EPOKSİ ÜRÜNLER
-
Floor Coatings
- PRIMER WG 032
- WALL WG 034
- BRV SC 105
- BRV SC-200 K
- PRIMER SC 210
- PRIMER SC 215
- PRIMER SC 220
- SC Z-230
- PRIMER SC 270
- PRIMER SC 325
- DECOFLOOR SC 330
- FLOOR SC 470
- SC 600
- WALL SC 605
- WALL SC 605-C
- BRV SC 610 SOLVENTSİZ EPOKSİ SON KAT BOYA-ENG
- BRV SC 620 SOLVENTSİZ TEKSTÜRLÜ EPOKSİ SON KAT BOYA-E
- BRV SC 625 SOLVENTSİZ EPOKSİ SON KAT KAYMAZ ZEMİN BOYASI-E
- FLOOR SC 645
- SC 650 ST
- FLOOR SC 902
- FLOOR SC 903
- BRV SC 905 • DÜŞEY YÜZEYLER İÇİN KİMYASAL MADDELERE DAYANIKLI SOLVENTSİZ EPOKSİ SON KAT BOYA
- FLOOR SC 950
- FLOOR SC 1200
- FLOOR AC 6380
- ROAD AC 6388
- Waterproofing Products
- Repair Anchorage and Assembly Products
- Joint Filler and Ceramic Adhesive Products
- Wood Protection Adhesive and Lamination Products
- Natural Stone Protectors
- Water Reservoir & Drainpipe Insulation Products
- Anticorrosive Products For Metal Surfaces
- Thinners
-
Floor Coatings
-
POLIURETAN PRODUCTS
- ZEMIN KAPLAMA ve BOYAMA URUNLERI
- SU YALITIM URUNLERI
- YAPISAL GUCLENDIRME TAMIR ANKRAJ MONTAJ URUNLERI
- AHSAP KORUYUCU, YAPISTIRICI ve LAMINASYON URUNLERI
- DOGALTAS KORUYUCU URUNLER
- METAL YUZEYLER ICIN ANTIKOROZIF URUNLER
- Concrete Protection and Shining Products
- TINERLER
-
AKRILIK PRODUCTS
- SU YALITIM URUNLERI
- ZEMIN KAPLAMA ve BOYAMA URUNLERI
- Indoor & Outdoor Insulation and Painting
- Fire Retardant Insulation Paint
WALL SC 605-C
DEFINITION
USAGE AREAS
It is an Epoxy top layer paint with two components, without solvent for vertical surfaces with high mechanical endurance and wear resistance, easy to clean and can be used in factories, assembly workshops, depots, aircraft hangers, store, auto-park, food facilities, water tanks, hospitals, chemical and drug industry, energy power plants, in units where hygiene is desired, on surfaces where plaster has been applied and all industrial areas .
Type | TS EN 1504-2/ April 2008 Principle 5(PR): 5,1 Physical Resistance / Surface Improvement Coating Application ( C ) |
Color | RAL colors |
Appearance | Bright |
Solid Matter By Weight, % | 95 |
Density | 1,55 g/cm³ |
Waste | 0,200-0,500 kg/m² |
Package | 20 kg A Component + 4 kg B Component: Total 24 kg |
Flash Point | >25 °C |
Mixture Ratio | 5 / 1 |
Application Methods | Brush, Roller, Airless Gun, |
Mixture Life | 30 minutes/ 25°C |
Shelf Life | 1 year |
Waiting Time Between Coating | 12 hours/ 25°C |
Drying Time | 12 hours / 25°C |
Mechanical strength | 7 days |
Shore D Hardness Fire Reaction Class | 70 (7 days / 25°C) C |
Equipment Cleaning | Epoxy Thinner |
* The surfaces to be applied should be clear of grease, dust and dirt.
* Free particles on surfaces, cement slurry on cement surfaces and parts that prevent gluing should be cleared.
* Yüzeydeki serbest parçalar, beton yüzeylerdeki çimento şerbeti ve
yapışmaya engel olan parçalar temizlenmelidir.
MIXTURE PREPARATION
The components A and B should be mixed for at least 3-4 minutes with the aid of a low speed mixer until a homogeneous mixture is obtained, taking into account the mixing ratios. It is ready for application after mixing
COATING SYSTEM
The concrete surface where application would be done should be primed using SC 210 multi-purpose Epoxy Primer, SC 215 Epoxy Primer without Solvent or SC 270 Low Viscosity Epoxy Impregnated Primer. On moist surfaces SC 220 should be used and on 100% moist surfaces Epoxy Primer. 12 hours after the priming process, epoxy painting process can start. In brush or roller applications, epoxy brush or roller should be used. If it is necessary, the product itself can also be used as the first layer primer. In applications over plaster, prior to using SC 605 Epoxy Top Layer Pint without solvent, water based acrylic BRV Primer 405 should be applied as transition primer. In cases where high UV durability is desired, it is suggested to apply P125 protective coating with 0,150 – 0,200 kg/m² waste.
APPLICATION CONDITIONS
* The surfaces must have sufficient endurance. Concrete should endure minimum 25 N/mm² pressure and endure against at least 1,5-2 N/mm² pull-off strength.
* The surface should be clean, straight, dry and should not exceed 5% moisture and if moisture is above this rate, SC 220 should be used on moist surfaces and Epoxy Primer on 100% moist surfaces.
* The priming should have completed its curing prior to moving on to the top layer epoxy painting process.
* Application should be avoided under 10°C and in high moisture environments.
* The mixture ratios should be paid attention to.
Products suggested to be used under this product :
* SC 210 Multi-purpose Epoxy Primer
* SC 270 Epoxy adhesion bridge Low Viscosity Impregnated Primer