E-KATALOGLAR
RAL K7 Classic
Teknik Şartnameler
MAKİNA PARKURUMUZ
E-KATALOGLAR
RAL K7 Classic
Teknik Şartnameler
MAKİNA PARKURUMUZ

FLOOR SC 950

DEFINITION

Two component solvent free chemical resistant epoxy topcoat coating. Public Works Pos. No: 04.379/H03

USAGE AREAS

It is used as topcoat coating on surfaces exposed to chemical substances of ceramic walls, laboratories, hospitals, food facilities, swimming pools, thermal pools, water tanks, treatment plants, toilets, industrial plants.

Type

TS EN 1504-2 / April 2008 Principle 5 (PR): 5,1 Physical Resistance / Surface Improvement Coating Application ( C )

Colour

RAL colours

Outlook

Bright

Solid Matter by Weight, %

100

Density

1,50 g/cm³

Waste

0,500 – 1,200 kg / m2

Package

20 kg A Component + 5 kg B Component: Toplam 25 kg

Flash Point

>25 °C

Mixture Ratio

4/1

Application Methods

Brush, Roller, Airless Gun, Trowel

Mixture Life

30 minutes /  25°C

Shelf Life

1 year

Waiting Time Between Coats

12 hours /  25°C

Drying Time

12 hours /  25°C

Mechanical Strength

7 days

Shore D Hardnes

75 (7 days / 25°C)

Equipment Cleaning

Epoxy Thinner

SURFACE PREPARATION

* The surfaces to be applied must be free from oil, dust, and dirty.

* Free parts on the surface, cement grout on concrete surfaces and parts that prevent adhesion must be cleaned.

MIXING PREPARATION

A and B component should be mixed with a low speed mixer for at least 3-4 minutes until a homogenous mixture is obtained by paying attention to mixture ratios. It is ready for application after mixing.

COATING SYSTEM

The concrete surface to be applied must be primed with SC 210 Multipurpose Epoxy Primer - SC 215 Solvent Free Epoxy Primer or SC 270 Low Viscosity Epoxy Impregnated Primer. SC 220 Epoxy Primer for 100% Humid Surfaces should be used at humid surfaces. Chemical resistance epoxy coating can be applied after 12 hours of priming. The mixture is poured onto the surface to be applied and is spread equally to the surface by choicing toothed trowel depending on the desired thickness (1 mm or 2 mm of tooth spacing), The resulting air bubbles are removed by spiked roller. For brush or roller applications, an epoxy roller The concrete surface to be applied must be primed with SC 210 Multipurpose Epoxy Primer - SC 215 Solvent Free Epoxy Primer or SC 270 Low Viscosity Epoxy Impregnated Primer. SC 220 Epoxy Primer for 100% Humid Surfaces should be used at humid surfaces. Chemical resistance epoxy coating can be applied after 12 hours of priming. The mixture is poured onto the surface to be applied and is spread equally to the surface by choicing toothed trowel depending on the desired thickness (1 mm or 2 mm of tooth spacing), The resulting air bubbles are removed by spiked roller. For brush or roller applications, an epoxy roller must be used. Since the thickness of the roller should be 200-300 microns in these applications, 2-3 coats should be applied to reach the desired thickness. It is recommended to apply PU 125 protective coating with 0,150-0,200 kg/m² waste where high UV resistance is desired.

 

 

ENVIRONMENT

CONCENTRATION

STORAGE TEMPERATURE

STABILIZATION DURATION AND EVALUATIONE   7 DAYS     1 MONTH     6 MONTHS    12 MONTHS

ACETIC ACID

% 2

90°C

X

X

X

XX

LACTIC ACID

% 10

20°C

X

XX

XX

XX

CITRIC ACID

% 10

20°C

X

X

X

XX

AMMONIAC

% 25

20°C

XX

XX

XX

XX

HYDROGEN PEROXIDE

% 1

90°C

X

XX

XX

XX

IRON SULFATE

% 20

20°C

XX

XX

xx

Xx

SODIUM HYPOCLORITE

% 12 - % 16

90°C

X

X

X

XX

ALCOHOL

% 98

20°C

x

x

x

X

FORMALDEHYDE

% 20

20°C

x

x

xx

Xx

CAUSTIC

% 2

90°C

x

x

x

X

PHENOL

20°C

x

x

x

Xx

PHOSPHORIC ACID

% 10

20°C

x

x

x

X

SODIUM SULFATE

% 8

90°C

x

x

x

X

FORMIC ACID

% 5

20°C

x

x

x

X

SALTWATER

% 8

90°C

x

x

x

X


APPLICATION CONDITIONS


* Surface should have sufficient strength. The concrete has a compression strength of at least 25 N/mm², nd a tensile strength of at least 1,5-2 N/mm².

* The surface must be clean and dry. Humidity must not exceed 5%, If the humidity is above this ratio, SC 220 100% Epoxy Primer for humid surfaces used on humid surfaces should be preferred.

* The primer to be used must have been completed its curing before the top coat application of chemical resisrance floor covering system is started.

* Avoid application in very humid environments and below 10°C.

* Mixing ratios should be considered.