E-KATALOGLAR
RAL K7 Classic
Teknik Şartnameler
MAKİNA PARKURUMUZ
E-KATALOGLAR
RAL K7 Classic
Teknik Şartnameler
MAKİNA PARKURUMUZ

BRV SC-200 K

DEFINITION

Two component, ready-to-use epoxy self leveling intercoat prime>

Public Works Pos. No: 04.379/H02 />

USAGE AREAS

It is used in factory and warehouse floors, working areas, loading zones, industrial floors exposed to medium and heavy loads, to provide thickness and mechanical strength between primer and top coat in epoxy & polyurethane coating applications.

Type

TS EN 1504-2/April 2008 Principle 5(PR): 5.1 Physical Resistance / Surface Improvement Coating Application C

Colour

RAL

Outlook

Bright

Solid Matter by Weight, %

96

Density

1,55 g/cm³

Waste

0,300 – 0,800 kg / m2

Package

24 kg A Component + 4 kg B Component :  Total 28 kg

Flash Point

>25 °C

Mixture Ratio

6 / 1

Application Methods

Brush, Roller, Trowell

Mixture Life

40 minutes / 25 °C

Shelf Life

1 year

Waiting Time Between Coats

12 hours / 25 °C

Drying Time

12 hours/ 25 °C

Mechanical Strength

7 days

Equipment Cleaning

Epoxy Thinner

SURFACE PREPARATION


Y Free particles and paint residues on the surface must be thoroughly cleaned, brokens and cracks must be repaired, surfaces should be roughened mechanically (blastrack or milling router) and cleaned from vacuum with vacuum cleaner. After priming with SC 215 Solvent Free Epoxy Primer or SC 270 Low Viscosity Impregnated Primer, application should be started.

MIXING PREPARATION
A and B component should be mixed with a low speed mixer for at least 3-4 minutes until a homogenous mixture is obtained by paying attention to mixture ratios. It is ready for application after mixing.

COATING SYSTEM
Depending on the suction power of the surface, the primer waste varies between 0,300 and 0,800 kg/m².

APPLICATION CONDITIONS

* Surface should have sufficient strength. The concrete should have a compressive strength of at least 25 N/mm² and a tensile strength of at least 1,5 N/mm².

* The SC 200-K self leveling intercoat prime should be completed its curing before the top coat coating is started.

* Avoid application in very humid environments and below 5 ° C.

* Mixing ratios should be considered. Products that can be used upper this product:

* SC 650 ST Solvent Free Epoxy Resin Based Top Coat Coating

* SC 605 Epoxy Top Coat Paint for Vertical Surfaces

* SC 645 Orange Coat Patterned Top Coat Epoxy Coating

* SC 800 Hygienic Epoxy Top Coat Coating and Paint for Potable Water Reservoir

* SC 902 Solvent Free Epoxy Top Coat Coating

* SC 905 Solvent Free Epoxy Paint Resistant to Chemical Matter for Vertical Surfaces

* SC 950 Solvent Free Epoxy Coating Resistant to Chemical Matter