E-KATALOGLAR
RAL K7 Classic
Teknik Şartnameler
MAKİNA PARKURUMUZ
E-KATALOGLAR
RAL K7 Classic
Teknik Şartnameler
MAKİNA PARKURUMUZ

METAC PU 123

DEFINITION

Two component acrylic polyurethane topcoat paint with low solvent content.

USAGE AREAS

It is used as a topcoat anticorrosive paint on all kinds of metal surfaces which are primed in petrochemical plants, refineries and port facilities, fuel depots, power plants, pipelines, industrial vehicles, cranes, wagons and containers where UV resistance is required.

Type

TS EN ISO 12944-5

Colour

Ral colours

Outlook

Semi Matt

Thinner

Polyurethane Thinner

Solid Matter by Weight, %

70

Density

1,30 g/cm³

Waste

For 40 micron at single coat 70 gr / m2

Package

18 kg A Component + 2 kg B Component: Total 20 kg

Flash Point

>25 °C

Mixture Ratio

9/1

Application Methods

Brush, Roller, Air Gun, Airless Gun

Mixture Life

1 hours/25 °C

Shelf Life

1 year

Waiting Time Between Coats

4 hours/25 °C

Drying Time

4 hours/25 °C

Mechanical Strenght

7 days

Equipment Cleaning

Polyurethane Thinner

SURFACE PREPARATION

Before applying the primer coat, the free particles, paint residues, oil, dirt and dust on the surface must be thoroughly cleaned, brokens and cracks must be repaired and the surface must be absolutely roughened before application.

MIXING PREPARATION

A and B component should be mixed with a low speed mixer for at least 3-4 minutes until a homogenous mixture is obtained by paying attention to mixture ratios. It is ready for application after mixing.

APPLICATION CONDITIONS

* Application should not be applied if the ambient and surface temperature is below +10 ºC or above +30 ºC.

* Avoid application in rainy and windy weather.

* It must be protected against water for at least 24 hours after painting is completed.

* Relative humidity must not exceed 70% when applied.

Products that can be used under this product:

* AC 2480 Epoxy Intermediate Primer

* AC 070 Epoxy Zinc Rich Prime

* AC 080 Surface Tolerant Epoxy Primer