DEFINITION

Two component UV resistant flexible aliphatic polyurethane clear protective coating.

USAGE AREAS

It is used where it is desired to protect the surface from UV rays, on ceramic surfaces of terraces, roofs and swimming pools, in the insulation of the capillary cracks between the joints, on natural stone, wood, brick, concrete surfaces, where strength and dustiness against chemical substances, impact, abrasion are required.

 

Type

 

TS EN 1504-2/April 2008 Principle 5(PR): 5.1 Physical Resistance / Surface Improvement Coating Application C

Colour

Transparent

Outlook

Bright

Solid Matter by Weight, %

40

Solid Matter by Volume, %

35

Density

0,97 g/cm³

Waste

55 gr/m2- 95 gr/m2 (For 20-30 micron dry film tickness)

Package

17,5 kg A Component +  3,5 kg B Component:  Total 21 kg

Flash Point

>25 °C

Mixture Ratio

5  / 1

Application Methods

Brush, Roller, Air Gun, Airless Gun

Mixture Life

1-1,5 hours/25 °C

Shelf Life

1 year

Waiting Time Between Coats

2 hours/25 °C

Drying Time

6 hours/25 °C

Mechanical Strength

7 days

Equipment Cleaning

Polyurethane Thinner

SURFACE PREPARATION

Free particles in the surface, paint residues, oil and dirties must be completely cleaned, brokens and cracks must be repaired and the surface must be absolutely roughened before application

MIXING PREPARATION

A and B component should be mixed with a low speed mixer for at least 3-4 minutes until a homogenous mixture is obtained by paying attention to mixture ratios. It is ready for application after mixing

APPLICATION CONDITIONS

* The surfaces must be free from humid and dust.

* Avoid application in very humid environments and below 10°C..

* Mixing ratios should be considered.

* Relative humidity must not exceed 70% when applied.