COALTAR AC 2800

DEFINITION

Solvent free epoxy coal tar paint with two component

USAGE AREAS

It is used for the protection of steel and concrete structures buried in water and soil, for insulations of tank and treatment plant. As it can be applied alone, it can be applied on epoxy primer and intermediate layers. It’s resistance to wear, rust, salt water and chemicals is high.

Type  TS 11589
Colour Black
Outlook Bright
Thinner Epoxy Thinner
Solid Matter by Weight, % 100
Density 1,21 g/cm³
Waste 50 gr/m² for metal surfaces for 40 microns to single surface
150 – 250 gr/m² for single layer on concrete surfaces
Package 14 kg A Component + 7 kg B Component: Tota 21 kg
Flash Point >25 °C
Mixture Ratio 2 / 1
Application Methods Brush, Roller, Air Gun, Airless Gun
Mixture Life 30 minutes / 25°C
Shelf Life 1 year
Waiting Time Between Coats 12 hours / 25°C
Drying Time 12 hours/ 25°C
Mechanical Strength 7 days
Equipment Cleaning Epoxy Thinner

SURFACE PREPARATION

All materials must be primed, clean and dry. The surfaces to be applied should be cleaned from oil, dust, etc.. Pre-painted and composite surfaces should be cleaned with epoxy thinner, then sanding with 80-120 sand corundum must be done.

MIXING PREPARATION

A and B components should be mixed with a low speed mixer for at least 3-4 minutes until a homogenous mixture is obtained by paying attention to mixture ratios. It is ready for application after mixing.

COATING SYSTEM

It can be applied by brush, roller and spray. Thinner is used for thinning in spray application. Paint thinned to viscosity at 18-20 sec/DIN CUP4/20°C can be applied with gun to give 35-40 micron dry film on metal. The prepared mixture is applied without diluting in brush or roller application.

APPLICATION CONDITIONS

* Avoid applications under 10°C and in very humid environments.

Products recommended for use under this product:
* AC 070 Epoxy Zinc Rich Primer