METOX AC 6390

DEFINITION

Two component, solvented, epoxy top coat paınt for metal surfaces

USAGE AREAS

It is used as topcoat paint in petro chemical plants, power plants, ship deck metal parts, steel constructions, iron and sheet metal products, galvanized or non-galvanized equipments.

 

Type

TS 11590

Colour

Ral colours

Outlook

Semi Matt

Thinner

Epoxy Thinner

Solid Matter by Weight, %

67

Density

1,40 g/cm³

Waste

For 40 micron at single coat 80 gr/m²

Package

20 kg A Component+ 5 kg B Component: Total 25 kg

Flash Point

>25 °C

Mixture Ratio

4 / 1

Application Methods

Brush, Roller, Air Gun, Airless Gun

Mixture Life

1,5-2 hours / 25°C

Shelf Life

1 year

Waiting Time Between Coats

6 hours / 25°C

Drying Time

8 hours/ 25°C

Mechanical Strenght

7 days

Equipment Cleaning

Epoxy Thinner

SURFACE PREPARATION

* The surfaces to be primed or painted should be cleaned of all kinds of rust, rolling bark, dirt, dust, oil and grease, roughened using mechanically appropriate abrasives.

* It is especially recommended to make sandblast at least SA 2½ degree according to Swedish standard SIS 05 59 00 for surface cleaning.

* Abrasives provided surface roughness Medium G 30-85 micron degree ISO 8503-2 should be used.

MIXING PREPARATION

A and B component should be mixed with a low speed mixer for at least 3-4 minutes until a homogenous mixture is obtained by paying attention to mixture ratios. It is ready for application after mixing.

COATING SYSTEM

It can be applied by brush, roller and spray. Thinner is used for thinning in spray application. Paint thinned to viscosity at 18-20 sec/DIN CUP4/20°C can be applied with gun to give 35-40 micron dry film on metal. The mixture prepared by application with brush or roller is applied without diluting.

APPLICATION CONDITIONS

* Avoid application in very humid environments and below 10°C.

* Winding may occur in environments exposed to direct sunlight, but does not adversely affect the protective performance of the product.

Products that can be used under this product:

* AC 070 Epoxy Zinc Rich Primer

* AC 080 Surface tolerate Epoxy Prime

* AC 2480 Epoxy Intermediate Coat Primer