SEAL SC 2000

DEFINITION

Two component, solvent free epoxy, coal tar modified liquid insulation membrane

USAGE AREAS

It pastes concrete together by entering between cracks formed in concrete, basement, groundworks, pond, pier, bridge feet, foseptic isolation, foundation of buildings.When it is applied on the supporting columns and the curtain concrete of the buildings, it prevents that floor waters penetrates to concrete so it prevents both the corrosion of the concrete and the corrosion of the iron in the concrete. It is not affected by internal and external pressures, it does not separate from the surface, it reacts with the concrete and becomes an integral part of the concrete. On concrete floors of oil storage tanks, it is used with purpose to prevent oil from mixing with soil, it is resistant to salt water. Resistance to chemical substances is high.

 

Type

TS 11589

Colour

Dark Brown

Outlook

Matt

Solid Matter by Weight, %

100

Density

1,40 g/cm³

Waste

0,500-1,500 kg / m2

Package

16 kg A Component + 8 kg B Component:Tottal 24 kg

Flash Point

>25 °C

Mixture Ratio

2 / 1

Application Methods

Brush, Roller, Trowell, Airless Gun

Mixture Life

30 min /  25°C

Shelf Life

1 year

Waiting Time Between Coats

12 hours /  25°C

Drying Time

12 hours /  25°C

Mechanical Strength

7 days

Equipment Cleaning

Epoxy Thinner

* The surfaces to be applied must be free from oil, dust, and dirty. Free parts on the surface, cement grout on concrete surfaces and parts that prevent adhesion must be cleaned.

MIXING PREPARATION

A and B component should be mixed with a low speed mixer for at least 3-4 minutes until a homogenous mixture is obtained by paying attention to mixture ratios. It is ready for application after mixing.

COATING SYSTEM

Prepared homogeneous mixture must be thoroughly poured onto the surface with roller or a suitable brush and it is applied to close the pores. If desired, it can be applied with air and airless gun. Carrier fiber application is recommended where water pressure is high. 7 days after it becomes resistant to chemicals. Screed, concrete, ceramic tile etc. can be easily laid on it. Before Seal SC 2000 epoxy coal tar modified liquid insulation membrane must completes its curing before top coat coating is started.

APPLICATION CONDITIONS

* Surface should have sufficient strength. The concrete should have a compressive strength of at least 25 N/mm² and a tensile strength of at least 1,5 – 2 N/mm².

* Surfaces must be clean, smooth and dry. Humid is not pass 5%. If the humidity is above this ratio, SC 220 Epoxy Prime for Humid Surfaces should be preferred.

* Before Seal SC 2000 epoxy coal tar modified liquid insulation membrane is started, SC 220 Epoxy Primer for 100% Humid Surfaces must completes its curing..

* Avoid application in very humid environments and below 10°C.

* Mixing ratios should be considered.