- Home
- Polyurethane Products
- Polyurethane Floor Covering and Painting Products
- POLIFLEX PU 126 POLYURETHANE FLEXIBLE PAINT
POLIFLEX PU 126 POLYURETHANE FLEXIBLE PAINT
- General Details
- Product Features
- Implementation
- İlgili Görseller
DEFINITION
USAGE AREAS
It is applied on polyurea and polyurethane insulation systems as a protective coating.
|
Colour |
Ral colours |
|
Outlook |
Bright |
|
Thinner |
BRV PU 012 Polyurethane Thinner |
|
Solid Matter by Weight, % |
60 |
|
Density |
1,15 g/cm³ |
|
Waste |
50-100 gr / m2 |
|
Package |
19 kg A Component + 3 kg B Component: Total 22 kg |
|
Flash Point |
>25 °C |
|
Mixture Ratio |
6,33 / 1 |
|
Application Methods |
Brush, Roller, Air Gun |
|
Mixture Life |
40 min./25 °C |
|
Shelf Life |
1 year |
|
Waiting Time Between Coats |
2 hours/25 °C |
|
Drying Time |
12 hours/25 °C |
|
Mechanical Strenght Flexibility (ISO 1519 ) Solar Reflectance (Initial) SRI (Solar Reflectance Index-Initial ) |
7 days 6 (0.6 mm cold rolled steel panel 5 cm x 10 cm) 0.88 (ASTM C 1549)-(RAL 9016) 110 (ASTM E 1980)-(RAL 9016) |
|
Equipment Cleaning |
Polyurethane Thinner |
SURFACE PREPARATION
Prior to applying the primer coat, free particles in the surface, lime and chlorine residues in pool applications, paint residues, oil, dirt and dust must be thoroughly cleaned, brokens and cracks must be repaired and the surface must be absolutely roughened by corundum before application
MIXING PREPARATION
A and B component should be mixed with a low speed mixer for at least 3-4 minutes until a homogenous mixture is obtained by paying attention to mixture ratios. It is ready for application after mixing.
APPLICATION CONDITIONS
The surfaces must be free from humid and dirty
* Avoid application in very humid environments and below 10°C.
* Mixing ratios should be considered.
* Relative humidity must not exceed 70% when applied.
** If the application surface completes the 7 day chemical resistance period, Poliflex PU 126 Polyurethane Flexible Paint should be applied in 2 coats. 1st coat should be applied as primer coat with maximum 100 gr/m2 waste by thinning with 10% PU 012 Polyurethane Thinner. On 2nd coat, Poliflex PU 126 Polyurethane Flexible Paint application should be started.